• Thank you for purchasing COMMAX products.• Please carefully read this User’s Guide (in particular, precautions for safety) before using a product an
- 9-5. Setting PIN5-1. Management PIN Setup✽ P - Old Management PIN - E - 0 - E - New PIN -E✽ Management PIN must be 4-digits long.✽ 0000 will not be
- 10 -5-2. Building PIN Setup✽ P - Old Management PIN - E - 1 - E - New PIN - E✽ Building PIN must be 4-digits long.✽0000 will not be recognized as a
- 11 -5-3. Household PIN Setup✽K - Program Number - E - Household Number - E - Old Household PIN - E - New PIN - P✽ Household PIN must be 4-digits lon
- 12 -6.Household PIN Confirmation6-1. Household PIN Confirmation✽ P - Management PIN - E - Program Number - E - Household Number - E① Press the Progr
- 13-✽① Press the Program button (P). (‘Prog’will appear)② Enter the Management PIN.③ Press the Call button (E).④ Press the Program Number (3) .⑤ Pr
- 14-8. Using Remote Cardkeys (RF/ID) - Optional8-1. Testing Remote Cardkeys✽ P - Management PIN - E - 9 - E - Card Test - X (Cancel)✽ This feature is
- 15-8-2. Remote Cardkey Registration✽ P - Management PIN - E - 10 - E - Card Registration - X (Cancel)<Note>CdSv: Newly Registered Card (Succes
- 16-8-3. Individual Deletion of Remote Cardkeys✽ P - Management PIN - E - 12 - E - Card Deletion - X (Cancel)① Press the Program button (P). (‘Prog’w
- 17-8-4. Confirming Remote Cardkey Registration✽ P - Management PIN - E - 13 - E - Card Confirmation - X (Cancel)① Press the Program button (P). (‘Pr
- 18-8-5. All Remote Cardkey deletion✽ P - Management PIN - E - 11 - E - E✽ Refrain from deleting all Remote Cardkeys, except for during installation.
- 1-the Main Entrance Interphone (RF/ID) - Optional9. Electronic key setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
- 19-9. Electronic key setting ✽ P - Management PIN - E - 8 - E - 0 – E : Deactivate usage of electronic keys (Available PIN number access) ✽P - Mana
- 20-10. Door Release Time Setup✽ P - Management PIN - E - 4 - E - Door Release Time - E ✽This feature adjusts the door release time.① Press the Progr
11. Line Call Setup ✽ P - Management PIN - E - 21 - E - 0 - E : All calls ✽P - Management PIN - E - 21 - E – 0103 - E : Line call ex) This function is
- 22-✽P - Management PIN - E - 5 - E - 0 - E: Melody Tone ✽ P - Management PIN - E - 5 - E - 1 - E: Bell (Ringer)✽This feature sets the Recall tone he
- 23-✽ P - Management PIN - E - 7 - E - 0 - E: Constant call✽P - Management PIN - E - 7 - E - 1 - E: Call once✽This function is to set the call sound
- 24-Press the Program button (P).Enter the Management PIN.Press the Call button (E).The current capacityis displayed.Press the Call button (E).Press
- 25-15. Input Household number✽ P - Management PIN - E - 15 - E - Household Number - E-Multi Sub number - E ✽ This function is for inputting househol
- 26-<Multi sub number>✽ What is Multi sub number? In case that one household have more than one unit, assigned number to identifyevery unit for
- 27-Enter theHousehold Number.Press the Guard button. Press the Page button.A paging tone will sound.Wait for a replyWait for a replyPress the page b
- 28-✽ Household Number - K - Household PIN - E✽O - K - Building (Management) PIN - EEnter the Household Number.Press the Guard button.Enter the House
Please follow the things described below in order to prevent anydanger or property damage.WarningCautionProhibition.No disassemblyNo touchMust follow
- 29-✽ Various PIN Programs1. P - Old Management PIN - E - 0 - E - New PIN- E: Management PIN Change 2. P- Old Management PIN -E -1 - E - New PIN - E:
- 30-✽ Calling to household from lobby phone✽ Household number – EPress the household number Press the Call button.ex)In case of household 101 Emit ca
22. Wiring Method1) Lobby camera phone(DRC-GAC/GAB)- 31-
2) System Schematic- 32-
3) Terminal Board Wiring Diagram- 33-
3) DRC-GAC Expansion- 34-
※Please carefully read this User’s Guide before calling service man After checking the entire check list, please contact customer service center. Wewi
513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, KoreaInt’l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133Web site : w
- 3-Cleaning & UsePlease don’tdisassemble,repair or rebuild this productarbitrarily (please contact theservice center if a repair isneeded. ·It ma
- 4 -3-1. Part name①②③④⑤⑥⑨⑩⑪⑫⑬⑭⑧⑦3. Overview No FUN No FUN1. C-MIC 2. CAMERA 3. SPEAKER 4. FND DISPLAY 5.
- 5-3-2 Essentials✽ RF/ID Receiver ⑤ (Optional)To open the door using a Remote Cardkey, place the key here. The word ‘oPEn’willdisplay and the door wi
- 6-✽ Cancel Button ⑪ (X: Cancel)This button is used to cancel the current operation.✽ Talk volume controller ⑬Talk volume is adjustable by switching
- 7-● Must Know Before Use!1) Accessing All Features with the Program Button-When an error has been made as indicated by continuous beeps, pleasecance
- 8-4. PIN Types4-1. Management PIN- This PIN is for use by the person in charge of the Management Office.- By default, this PIN is set as 4321.- Mana